1.1015 4thaxis clamped
2.1016 5thaxis clamped
This alarm occurs when the pressure to the axis is less, this cause in the movement of the axis while job is going and results in the damaging work piece. The clamp is nothing but a disc break uses to hold the axis tightly in the work position. The pressure detecting device is a pressure switch placed parallel to the hydraulic oil hose. For example the required pressure to give good breaking is 5 bar, we need to set the pressure switch setting to 5 bar. The possible causes to occurring alarm are
1.The hydraulic pump is delivering less pressure.
2.The electric relay which operates the solenoid valve is not working. (Check the relay output, we can find the output in PMC signal status)
Y5.4 – M40 Clamp Relay, Y5.5 – M41 Unclamp Relay.
Y31.2 – M50 Clamp Relay, Y313 - M51 Unclamp Relay.
3.The solenoid which releases the hydraulic pressure to the tank (Results freeing the hydraulic break) is defective.
4.The pressure switch itself is defective.(We can find the feedback if the pressure switches in PMC Signal Status)
X6.5 – 4thaxis M40 Clamp Finish, X6.7 – 4th axis M41 Unclamp Finish.
X36.2 – 5thaxis M40 Clamp Finish, X36.3 – 5th axis M41 Unclamp Finish.
After troubleshooting the problem for checking run the following program in MDI mode
For 4th Axis
M121 – Call pallet A
M41 - 4thaxis unclamp
GO B50 – Angele of rotation in Degrees
M40 – 4thaxis clamp
M30 – Program Rewind
For 5th Axis
M122 – Call pallet B
M51 – 5Sthaxis unclamp
GO B50 – Angele of rotation in Degrees
M50 – 5thaxis clamp
M30 – Program Rewind
No comments:
Post a Comment